Description
- Gas Control Valve
- Type 1-Stage
- Direct Ignition
- Intermittent Pilot
- Straight-Through
- Slow Opening
- Nominal Size 3/4 Inch
- End Connection Female Threaded x Female Threaded
- End to End Distance 4-1/16 Inch
- Supply Connection 1/4 Inch Quick Connect Male Terminal
- Input Supply Rating 24 Volt AC at 60 Hertz
- Temperature Rating 0 to 175 Deg F
- Pressure Rating 1/2 PSI
- Inclusions/Features Natural to Liquid Propane Conversion Kit
- (2) 3/4 Inch x 1/2 Inch Reducer Bushing
- Application Gas Fired Appliance
- Applicable Standard UL
- CSA
- Overall Dimension 2-11/16 Inch Depth x 5-3/8 Inch Height
- Fuel Type Natural
- Flow Capacity 30000 BTU/Hour (Minimum)
- Pressure Tapping Size 1/8 Inch Threaded with Plug
- Pressure Regulator Set Point 3.5 Inch WC